| Area | Basis | Lessons | Treatment and separate evidence |
|---|---|---|---|
| FBF-001 — Separate evacuation, brigade and system roles | 29 CFR 1910.155, 1910.156(a), 1910.159(a)–(b), 1910.160(a) | scope | Identify the actual role, system and applicable rule before assigning work. Identify the actual role, system and applicable rule before assigning work. |
| FBF-001 — Define the brigade before an emergency | 29 CFR 1910.156(b) | organization | Locate the written statement and explain your assigned response boundary. Locate the written statement and explain your assigned response boundary. |
| FBF-001 — Match brigade training to duties and frequency | 29 CFR 1910.156(c)(1)–(3) | training | Build a role-based schedule with pre-duty instruction, annual training and quarterly interior sessions. Build a role-based schedule with pre-duty instruction, annual training and quarterly interior sessions. |
| FBF-001 — Teach special hazards and changes | 29 CFR 1910.156(c)(4) | special_hazards | Find current special-hazard procedures and identify how changes reach each shift. Find current special-hazard procedures and identify how changes reach each shift. |
| FBF-001 — Keep brigade equipment ready | 29 CFR 1910.156(d) | equipment | Report defects and verify suitable replacement before equipment is relied upon. Report defects and verify suitable replacement before equipment is relied upon. |
| FBF-001 — Recognize interior protection and respiratory prerequisites | 29 CFR 1910.156(e)–(f); 1910.134 | protection | Verify the separate protective and respiratory program before any interior assignment. Verify the separate protective and respiratory program before any interior assignment. |
| FBF-001 — Train people for their fixed-system functions | 29 CFR 1910.160(a), (b)(1), (b)(10) | fixed_roles | Identify designated system personnel and verify task-specific training and annual review. Identify designated system personnel and verify task-specific training and annual review. |
| FBF-001 — Manage an impaired system | 29 CFR 1910.160(b)(2); 1910.159(c)(4); 1910.165(d)(3) | impairment | Report impairment and verify temporary protection, repair and handover. Report impairment and verify temporary protection, repair and handover. |
| FBF-001 — Distinguish system inspections from training | 29 CFR 1910.160(b)(6)–(10) | fixed_inspection | Separate equipment condition records from employee training and close service discrepancies. Separate equipment condition records from employee training and close service discrepancies. |
| FBF-001 — Recognize discharge hazards and leave safely | 29 CFR 1910.160(b)(4)–(5), (b)(17), (c); 1910.161–163 | agents | Explain the discharge alarm, safe exit and controlled reentry arrangement. Explain the discharge alarm, safe exit and controlled reentry arrangement. |
| FBF-001 — Protect sprinkler and standpipe readiness | 29 CFR 1910.159; 1910.158 | sprinklers | Keep discharge and access areas clear and refer testing and changes to designated personnel. Keep discharge and access areas clear and refer testing and changes to designated personnel. |
| FBF-001 — Use trained personnel for detection systems | 29 CFR 1910.164 | detection | Report detector problems without disabling or adjusting the device yourself. Report detector problems without disabling or adjusting the device yourself. |
| FBF-001 — Recognize alarms and keep reporting available | 29 CFR 1910.165; 1910.38 | alarms | Identify your alarm, reporting method, accessible warning and accountability location. Identify your alarm, reporting method, accessible warning and accountability location. |
| FBF-001 — Verify workplace readiness and separate qualifications | 29 CFR 1910.156(c), 1910.160(b)(10), 1910.164(c)(4), 1910.165(d)(5) | verification | Document demonstrated understanding, separate practical requirements and assignment restrictions. Document demonstrated understanding, separate practical requirements and assignment restrictions. |
Sources
- 29 CFR 1910.156 — Fire brigades
- 29 CFR 1910.158 — Standpipes and hose
- 29 CFR 1910.159 — Automatic sprinklers
- 29 CFR 1910.160 — Fixed extinguishing systems
- 29 CFR 1910.161 — Dry chemical
- 29 CFR 1910.162 — Gaseous agent
- 29 CFR 1910.163 — Water spray and foam
- 29 CFR 1910.164 — Fire detection
- 29 CFR 1910.165 — Employee alarms
- 29 CFR 1910.134 — Respiratory protection
- 29 CFR 1910.38 — Emergency action plans
- 29 CFR 1910.157 — Portable extinguishers
Federal OSHA sources reviewed October 23, 2026. Confirm the actual work, jurisdiction and applicable additional requirements. Agency guidance supports planning; it is distinguished from mandatory standard text.