Free toolbox talk · TBT-70

Carbon Monoxide: Keep Exhaust Out of the Work

Carbon monoxide cannot be detected by smell. Combustion equipment can contaminate enclosed or partly enclosed work areas, and exhaust outside can enter through openings or air intakes.

Download the free toolbox talk

The one-page talk, editable Word version, and guidance below are open to everyone. No account required.

Preview the one-page toolbox talkActual first page of Carbon Monoxide: Keep Exhaust Out of the Work; use the PDF download for readable full text

Supporting documents

Supervisor field checks and attendance records are included with a free account. No payment is required.

Supervisor field check

A separate check to verify conditions and controls before work. Includes a one-page PDF and editable Word file.

Attendance sheet

A separate sign-in sheet to record the toolbox talk. Includes a one-page PDF and editable Word file.

Need the crew records? Create a free account to use these supporting documents and Jenkins Academy of Applied Technology. No payment is required. Email updates are optional.

Create Free Account

Already have an account? Sign in

A 5–10 minute toolbox talk, plus the time needed for field verification. Toolbox talk downloads are public; supporting records are included with a free Safety account.

Why this matters

Carbon monoxide cannot be detected by smell. Combustion equipment can contaminate enclosed or partly enclosed work areas, and exhaust outside can enter through openings or air intakes.

Learning objective: Identify exhaust exposure paths and verify the prevention and response plan.

Key hazards or failure points

Indoor gasoline tools; exhaust entering occupied areas; ineffective ventilation; unsuitable monitoring; symptoms mistaken for fatigue; unprotected rescue.

Practical controls

  • Use suitable noncombustion equipment where feasible and assess its hazards. Do not use gasoline-powered tools or generators inside enclosed or partly enclosed areas.
  • Keep outdoor combustion sources where exhaust cannot enter occupied spaces. Have the responsible technical person assess source placement, exposure controls and monitoring needs.
  • Establish alarms, fresh-air escape and emergency help. Do not assume a dust mask, open doorway, household alarm or automatic engine shutoff makes an unsafe setup acceptable.

Verify It in the Field

Identify all combustion sources, including other crews’ equipment. Trace potential exhaust paths from a safe location and compare placement with the assessed plan and instructions.

The responsible person verifies required monitoring: suitable instrument, specified checks, locations and action criteria. Record the actual result and time. A running fan or absence of symptoms does not prove safe air.

Confirm everyone recognizes the alarm and knows the unobstructed fresh-air route and emergency call method. Resolve how safe reentry will be established; do not stage an exposure test.

Use the separate field check to record the acceptance source and criterion, safe method, checker, actual result and time. Mark VERIFIED, HOLD/NOT VERIFIED, or N/A with a reason. A checkmark alone is not evidence that protection works. Complete all required task checks; do not enter danger or improvise a test.

Examples of evidence to collect before exposure
ControlSafe verificationEvidence
Controlled exhaust pathCompare source locations and openings with the assessed plan.Equipment, placement, intake risks and correction.
Usable monitoringTrained person completes prescribed instrument and exposure checks.Instrument, check result, reading/time and applicable criterion.
Prompt escape and helpConfirm alarm recognition, route and emergency communication.Available route, contact method and unresolved gaps.

Stop and reassess

For an alarm or suspected poisoning, leave promptly to fresh air and summon emergency medical help. Do not delay escape to locate or shut down the source. Stay out of the affected area; do not attempt unprotected rescue. Reentry requires authorized assessment and verified safe conditions.

toolbox talk questions

  • Where could exhaust enter our work area?
  • Who verifies the monitoring and action criteria?
  • Where do we go and how do we get emergency help?

A situation to discuss

Illustrative situation: another crew starts a gasoline machine near an air intake. The work group stops the affected task and follows its exposure-response plan. The machine being outdoors does not by itself resolve the exhaust-entry hazard.

Leader preparation and practical detail

Prevent the source from reaching people

NIOSH recommends suitable alternatives to gasoline-powered equipment and warns against use in enclosed or partly enclosed spaces. An open door or a fan cannot be treated as permission for a hazardous engine placement. Outdoor equipment also needs assessment of nearby openings and air intakes. [1]

Make monitoring fit the workplace

The exposure assessment and applicable requirements determine monitoring needs and action criteria. Use the actual instrument instructions for readiness checks and operation, through appropriately trained personnel. This talk supplies no invented alarm threshold, calibration interval or reentry reading. Household detector advice does not establish that a workplace monitoring arrangement is adequate. [1, 2]

Do not wait for certainty before leaving

Headache, dizziness, nausea or confusion can occur with CO poisoning, but symptoms are not a reliable exposure detector and may have other causes. An alarm or suspected poisoning calls for prompt fresh air and emergency help. Do not send an unprotected coworker into the affected area or delay escape to find the source. Reentry belongs to the authorized assessment process. [1, 2]

Concrete work: apply this briefing to today’s task

Additional webpage guidance reviewed October 9, 2026. The existing one-page printable briefing and separate records retain their printed editions. Choose the relevant task questions below; do not read every section as one toolbox talk.

Enclosed concrete work: count every exhaust source

Before workers enter a curing enclosure or enclosed finishing area, compare today's equipment list with the exposure plan. Include heaters, finishing equipment, generators and engines used by adjacent crews. Assign someone to receive notice before another source is started or relocated.

Have the responsible person recheck exhaust paths and required monitoring after sheeting or doors change. Confirm safe entry and the fresh-air route under the site plan. A concrete-temperature sensor is not a CO monitor, and yesterday's air result does not verify a changed enclosure.

Record: Source inventory, enclosure changes, exposure assessment/monitoring reference, current findings, checker and entry decision.

Stop and reassess: An alarm or suspected poisoning means leave for fresh air and summon emergency help. Stay out until authorized assessment verifies safe conditions; do not attempt unprotected rescue.

Three crew questions

  • Which other crew could introduce exhaust?
  • Who reviews changes before workers enter?
  • Where is fresh air if this access route becomes unavailable?

Continue with Temporary Heaters: Check the Setup Before Use.

Use the Cold-Weather Concrete Protection JHA only within its stated ground-level, indirect-fired-outside scope; adapt the actual job plan.

Primary sources checked October 9, 2026: NIOSH — Carbon monoxide hazards at work. Apply the activity scope and current site requirements.

Use the separate supervisor record to capture the acceptance source, safe check method, assigned verifier, actual result and time. Hold affected work for an unresolved required control. Recheck and rebrief before authorized restart.

Short supervisor field check

  • Combustion sources and exhaust paths identified.
  • Suitable alternatives and safe placement assessed.
  • Required controls and monitoring verified.
  • Alarm, fresh-air route and emergency contact understood.
  • Authorized reentry and rescue arrangements established.

Record unresolved items, restrictions, correction owner, recheck result and required restart authorization. Reference permits and specialist inspections rather than treating this form as a replacement. Rebrief workers affected by a change.

Attendance and follow-through

Use the separate attendance sheet for participants, discussion concerns, actions and late-arrival rebriefs. Attendance does not establish competence, verify controls or authorize work. Keep completed records private under the employer’s recordkeeping procedures.

Technical scope and references

Workplace combustion-exhaust awareness. NIOSH and CDC sources are guidance, not a complete regulatory exposure program. Confined-space entry, rescue and respiratory protection require separate specialist programs. [1, 2]

References reviewed October 7, 2026. Apply the industry, activity and jurisdiction that govern the work. No actual site permit, equipment manual, exposure assessment or engineering determination was supplied for this general discussion.

  1. NIOSH — Carbon monoxide — Workplace sources, prevention, exposure and response guidance.
  2. CDC — Carbon monoxide poisoning basics — Public-health guidance on symptoms and combustion hazards; not industrial acceptance criteria.

Connect this discussion to your JHA/JSA

Use How to Conduct a Job Safety Analysis to connect task steps, hazards and controls. Revisit Pre-Job JHA/JSA: What Changed Today? when conditions change.

Work through the related Concrete Saw Cutting JHA, then adapt its assumptions to the actual work.

Related toolbox talks

Put one check into practice

Use the free JHA/JSA planning and field-verification worksheet to record today’s changes, important controls and the evidence needed before exposure.

Continue with a task-specific briefing